最新なNetwork ApplianceのNS0-506問題集無料の問題集

 

JapanCertにIT業界のエリートのグループがあって、彼達は自分の経験と専門知識を使ってNetwork Appliance NS0-506問題集無料に参加する方に対して問題集を研究続けています。

JapanCertを通じて最新のNetwork ApplianceのNS0-506問題集無料の問題と解答早めにを持てて、弊社の問題集があればきっと君の強い力になります。

NS0-506試験番号:NS0-506 日本語講座
試験科目:「NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP」
最近更新時間:2016-01-12
問題と解答:65

>> NS0-506 日本語講座

 

NO.1 A customer has a clustered Data ONTAP solution and needs to connect several Windows 2012
servers using iSCSI for LUN access.
Before the LUN can be seen, what must be configured on the host?
A. the iSCSI software initiator
B. the LUN partitioning
C. the Host Utilities Kit
D. the HBA queue depth
Answer: C

NS0-506日本語講座

NO.2 Which two flags would you use to enable NetApp thin provisioning on a LUN? (Choose two.)
A. -space-reserve enabled -space-allocation enabled
B. -space-reserve disabled -space-allocation enabled
C. -space-reserve enabled -space-allocation enabled
D. -space-reserve disabled -space-allocation disabled
Answer: C,D

NS0-506ダウンロード NS0-506試験対策

NO.3 A customer has recently deployed a clustered Data ONTAP 8.3 system and is trying to mount
LUNs to a Windows 2012 Server using the iSCSI protocol. They have enabled jumbo frames on their
nodes as well as their Windows 2012 Server. Whenever they attempt to scan for a new LUNs, Disk
Management times out and does not present any new storage.
What is causing the problem?
A. Clustered Data ONTAP 8.3 does not support the iSCSI protocol.
B. They have jumbo frames enabled on the host and storage, but not the Ethernet switches.
C. Windows 2012 does not support jumbo frames with the iSCSI protocol.
D. Clustered Data ONTAP 8.3 does not support jumbo frames with the iSCSI protocol.
Answer: B

NS0-506取得 NS0-506ガイド

NO.4 You are zoning a fabric for a clustered Data ONTAP storage system. After cabling, you see the
following addresses logged into the fabric:
20:04:00:a0:98:16:db:9c
50:0a:09:83:8d:b1:ce:c3
What should be included in the zone configuration?
A. 50:0a:09:83:8d:b1:ce:c3 and the initiator WWPN
B. 20:04:00:a0:98:16:db:9c and the initiator WWPN
C. 20:04:00:a0:98:16:db:9c and the initiator WWNN
D. 50:0a:09:83:8d:b1:ce:c3 and the initiator WWNN
Answer: A

NS0-506認定資格

NO.5 You have a large, heterogeneous SAN environment. You are asked to gather information for all
hosts, HBAs, switches, and storage. You are also told that you must collect this information over
network protocols without agents.
Which two NetApp tools allow you to perform this task? (Choose two.)
A. nSANity
B. OnCommand Unified Manager
C. OnCommand Report
D. OnCommand Insight
Answer: A,C

NS0-506会場

NO.6 You created a 5 TB VMware volume "vol_esx_nfs1" in "svm1" for an NFS datastore. The storage
efficiency savings of the vmdks are one over 50%, but the application team wants to minimize the
possibility of an out-of-space condition. You enable autogrow, autoshrink, and snapshot autodelete
with the following commands:
volume modify -vserver vm1 -volume vol_esx_nfs1 -space-mgt-try-first volume_grow
snapshotautodelete modify -vserver vm1 -volume vol_esx_nfs1 -enabled true -delete
orderoldest_first -target-free-space 10% -trigger volume
volautosize -vserver vm1 -volume vol_esx_nfs1 -mode grow_shrink -maximum-size 10 TB -
minimum-size 5 TB -grow-threshold-percent 80 -shrink-threshold-percent 60
What will these commands do?
A. Shrink the volume before deleting the Snapshot copies.
B. Increase the Snapshot copy reserve before growing the volume.
C. Grow the volume before deleting the Snapshot copies.
D. Delete the oldest Snapshot copies before growing the volume.
Answer: B

NS0-506試験合格 NS0-506受験記対策

JapanCertは最新のC9520-928問題集と高品質のM2090-626問題と回答を提供します。JapanCertのHP0-Y52 VCEテストエンジンと70-347試験ガイドはあなたが一回で試験に合格するのを助けることができます。高品質のC2150-463 PDFトレーニング教材は、あなたがより迅速かつ簡単に試験に合格することを100%保証します。試験に合格して認証資格を取るのはそのような簡単なことです。

NS0-506模擬試験: http://ns0-506-test-exam26.itdumps.xyz